LAVA supports the design of perforated wood shear walls with multiple openings in accordance with the 2021 Special Design Provisions for Wind and Seismic (SDPWS).
The Perforated Shear Wall Method allows engineers to account for windows, doors, and other openings without requiring a force transfer analysis around each individual opening.
LAVA automatically evaluates the openings, identifies full-height wall segments, and calculates the reduced shear wall capacity based on the perforated shear wall provisions.
Watch 🎥: Perforated Shear Walls with Multiple Openings
How Perforated Shear Walls Work in LAVA
When openings are added to a shear wall using the Perforated Method, LAVA evaluates the wall as a single perforated shear wall.
The analysis considers:
Overall wall length and height
Size and location of each opening
Full-height sheathed wall segments
Aspect ratios of full-height segments
Shear capacity reduction due to openings
Shear wall stiffness and deflection
The resulting capacity and deflection are used in the shear wall design and shear line analysis.

Perforated Shear Wall Design Requirements
LAVA performs several checks to determine whether a wall can be designed using the Perforated Method.
1. Maximum Wall Height
The Perforated Method in LAVA is limited to walls with an overall height of 20 feet.
For walls exceeding 20 feet, LAVA automatically switches to the Force Transfer Around Openings (FTAO) Method.
2. Shear Line Distribution Method
Perforated shear walls with openings require the Stiffness Method for shear line load distribution in LAVA.
SDPWS 2021 Section 4.3.5.5.1 and its commentary (C4.3.5.5.1) describe the distribution of shear forces to individual shear walls based on their relative stiffness. This approach assumes equal deflection along the shear line, with each wall resisting force in proportion to its stiffness.
For perforated shear walls, SDPWS Section 4.3.3.4 establishes the aspect ratio requirements and effective length adjustments for full-height wall segments.
LAVA requires the Stiffness Method for perforated shear walls with openings to account for differences in wall stiffness and ensure appropriate distribution of shear forces.
If the shear line is set to the Capacity Method, LAVA will flag the wall. Change the shear line distribution method to Stiffness to satisfy this requirement.
Code References: SDPWS 2021 Sections 4.3.5.5.1, C4.3.5.5.1, and 4.3.3.4.
3. Opening Location
Openings must be located at least 1 foot from both the top and side of the wall.
Minimum distance above an opening: 1 ft
Minimum distance from edge of wall to opening: 1 ft
Openings that do not meet these requirements cannot be designed using the Perforated Method in LAVA and error will be given.
4. Full-Height Wall Segment Aspect Ratios
LAVA checks the aspect ratio of each full-height sheathed wall segment.
For the Perforated Method, the aspect ratio is calculated using the overall wall height, rather than the clear height adjacent to an opening.
Aspect Ratio = Wall Height / Full-Height Segment Length
Use the full wall height for h, rather than the opening height. These provisions are addressed in §4.3.3.4.
In accordance with SDPWS Section 4.3.3.4:
Segment aspect ratio, h/b | Treatment |
|---|---|
≤ 2:1 | Use full segment length |
> 2:1 through 3.5:1 | Reduce its effective length by multiplying by 2b/h |
> 3.5:1 | Cannot count toward the resisting segment length |
These adjustments are used when calculating the available shear capacity of the perforated wall.
Perforated Shear Wall Capacity
The Perforated Method reduces the available shear capacity to account for the presence of openings.
LAVA calculates the opening adjustment factor, C₀, based on the total wall area, opening areas, and full-height sheathed area.
The nominal shear capacity is calculated using SDPWS Equation 4.3-5:
Vmax = vₙ × C₀ × Σbᵢ
Where:
Vmax = Nominal shear capacity of the perforated wall
vₙ = Nominal unit shear capacity
C₀ = Shear capacity adjustment factor
Σbᵢ = Sum of effective full-height shear wall segment lengths
Opening Adjustment Factor (C₀)
Per SDPWS Equation 4.3-6:
C₀ = A_wall / (3Aₒ + A_fhs) ≤ 1.0
Where:
A_wall = Total area of the perforated shear wall
Aₒ = Total area of openings
A_fhs = Total area of full-height sheathing
The full-height sheathed area used to calculate C₀ includes full-height sheathed segments regardless of their aspect ratio.
Aspect ratio adjustments are applied separately when determining the effective segment lengths used in Σbᵢ.

Effective Shear Wall Length
For full-height segments with aspect ratios greater than 2.0 and not exceeding 3.5, LAVA adjusts the effective segment length using SDPWS Section 4.3.3.4.
b_effective = b × (2b/h)
Where:
b = Actual full-height segment length
h = Overall wall height
Segments exceeding the maximum permitted aspect ratio are not included in the effective length used for shear capacity.
Reviewing the Calculation Results
LAVA includes the perforated shear wall calculations in the calculation report, allowing engineers to review the wall geometry, opening adjustment factor, effective wall lengths, and resulting shear capacity.

Summary
LAVA supports multiple openings in perforated shear walls and automatically performs the associated geometry, aspect ratio, and shear capacity checks.
Key requirements include:
Maximum wall height of 20 feet for the Perforated Method in LAVA
Stiffness Method required for shear line distribution
Minimum 1-foot clearance above and below openings
Full-height segment aspect ratio checks
Automatic opening adjustment factor and effective length calculations
For additional information on the alternative design method, see Force Transfer Around Openings (FTAO) – Shear Wall Design in LAVA.