Shear Walls with Openings

Prev Next

Available Design Methods

LAVA supports two methods for designing wood shear walls with openings:

1. Perforated Shear Wall Method

The Perforated Method allows multiple openings within a single shear wall, including windows and doors. LAVA evaluates the full-height wall segments and applies a capacity reduction factor based on the size and location of the openings.

This method requires specific detailing at the sole plate or sill plate and must meet the perforated shear wall requirements of SDPWS.

Learn more about Perforated Shear Walls with Multiple Openings

2. Force Transfer Around Openings (FTAO) Method

The FTAO Method accounts for the transfer of shear forces around an opening through the surrounding wall segments.

LAVA currently supports only one opening per shear wall using the FTAO Method. For walls with multiple openings, use the Perforated Shear Wall Method.

LAVA uses the Diekmann Method for FTAO analysis, which adjusts the design shear demand to account for the opening.

Learn more about Force Transfer Around Openings (FTAO)

Both methods are available in LAVA, allowing engineers to select the appropriate approach based on wall geometry, opening configuration, and detailing requirements.