Documentation Index

Fetch the complete documentation index at: https://help.cbs2llc.com/llms.txt

Use this file to discover all available pages before exploring further.

Flexible Diaphragm Verification Problem

Prev Next

Objective

This example demonstrates the design capabilities of lateral analysis of flexible diaphragms in LAVA.

Four-Story Wood Light-Frame Structure [Ref 1, Page 1]

Four-story wood-frame hotel, with lateral-load-resisting system consists of wood-frame bearing shear walls. The wood roof is framed with pre-manufactured wood trusses, with composition shingle roofing. The floor is framed with prefabricated wood I-joist, with 1-1/2” lightweight concrete topping.

Model Information

Model Name: LAVA-ATS.x1

LAVA-ATS
1.42 MB

Comparison

The following table shows the design results. The program gives reasonably close results with the reference [Ref 1].

Vertical Load Distribution Factor Cv

LAVA

[Ref 1]

Difference

Roof

0.31

0.31

0%

4th Floor

0.35

0.35

0%

3rd Floor

0.23

0.23

0%

2nd Floor

0.12

0.12

0%

Forces to Shear Wall A at All Levels

LAVA

[Ref 1]

Difference

Roof

1588

1587

0.1%

4th Floor

3383

3379

0.1%

3rd Floor

4579

4574

0.1%

2nd Floor

5177

5171

0.1%

Reference

[1]. 2021 IBC SEAOC Structural/Seismic Design Manual, Vol. 2