Objective

This example demonstrates the design capabilities of lateral analysis of flexible diaphragms in LAVA.

Four-Story Wood Light-Frame Structure [Ref 1, Page 1]

Four-story wood-frame hotel, with lateral-load-resisting system consists of wood-frame bearing shear walls. The wood roof is framed with pre-manufactured wood trusses, with composition shingle roofing. The floor is framed with prefabricated wood I-joist, with 1-1/2” lightweight concrete topping.

Model Information

Model Name: LAVA-ATS.x1

LAVA-ATS
1.42 MB

Comparison

The following table shows the design results. The program gives reasonably close results with the reference [Ref 1].

Vertical Load Distribution Factor Cv

LAVA

[Ref 1]

Difference

Roof

0.31

0.31

0%

4th Floor

0.35

0.35

0%

3rd Floor

0.23

0.23

0%

2nd Floor

0.12

0.12

0%

Forces to Shear Wall A at All Levels

LAVA

[Ref 1]

Difference

Roof

1588

1587

0.1%

4th Floor

3383

3379

0.1%

3rd Floor

4579

4574

0.1%

2nd Floor

5177

5171

0.1%

Reference

[1]. 2021 IBC SEAOC Structural/Seismic Design Manual, Vol. 2